Industrial Field Analog Isolation Amplifier Isolation Transmitter Bandwidth and Frequency Response Matching Selection Reference

Industrial Field Analog Isolation Amplifier Isolation Transmitter Bandwidth and Frequency Response Matching Selection Reference


Overview:

The input/output analog signal isolation amplifier (also known as analog isolation transmitter) between industrial field sensors and PLC/FCS/DCS and instrumentation belongs to the category of analog signal conditioning. Analog signal isolation amplifier can effectively protect all levels of control loop, eliminate or reduce the impact of environmental noise on the test circuit, inhibit the interference of common ground, frequency converter, electromagnetic valve and surge pulse on the equipment, and at the same time have signal limiting pressure on the lower-level equipment. Turbulence function. It is a reliable protection device for transmitter, instrumentation, frequency converter, solenoid valve, PLC/DCS input and output, and communication interface. For some harsh industrial sites, the control system is intricate and the high temperature, vibration, humidity, and interference signals coexist. Therefore, the input and output analog signals are amplified, converted, remotely transmitted, and the system circuits are completely isolated by the isolation amplifier. It is indeed the current automation control. One of the effective measures against interference in the system.


Bandwidth, also known as bandwidth, refers to the amount of data that can be transmitted at a fixed time, that is, the ability to transmit data in the transmission pipeline. In digital devices, the bandwidth is usually expressed in bps, which is the number of bits per second that can be transmitted. In analog equipment instruments, the bandwidth is usually expressed in cycles per second or hertz (Hz). The bandwidth of a signal refers to the frequency range occupied by various different frequency components contained in the signal.


The frequency response, referred to as frequency response, is used in electronics to describe the differences in the processing capabilities of a single instrument, PLC, and other devices for different frequency signals. Like distortion, this is also a very important parameter indicator.



The test method of the bandwidth index is as follows. Add an adjustable frequency sine wave analog signal at the input, and the output can stably follow the input signal. The maximum frequency range is the bandwidth. What is the engineering significance of the bandwidth indicator for industrial signal isolation amplifiers? How do we understand "bandwidth" in the application? The bandwidth index reflects the response speed of the isolation amplifier to the change of the input signal. The larger the bandwidth, the faster the isolation amplifier responds to signal changes; the smaller the bandwidth, the less sensitive the isolation amplifier reacts to the instantaneous change of the input signal, and in some cases it means that the anti-dry capability is stronger.


The working principle of the isolation amplifier and isolated transmitter is to first send the standard signals sent and received by sensors, instruments, PLCs, etc., or special signals such as temperature, displacement, frequency, and rotation speed to the semiconductor device to modulate, and then the sense of light or magnetic induction. The device performs isolated conversion and transmission, and then demodulates and restores the original signal with the same precision and linearity or converts it into other signals. At the same time, the isolated and processed signals are isolated to ensure signal input, signal output, and auxiliary power supply. That is, the isolation between the signal, power supply, and ground before and after the conversion. Analog signal isolation amplifiers and isolation transmitters are a device in the category of industrial instrumentation and sensors. Their main function is analog isolation, amplification, conversion, and transmission. Therefore, the signal bandwidth and frequency response are bound to be the basic Technical indicators.

Industrial site signal transmission interference treatment reference program (inverter anti EMC interference dedicated isolation amplifier):

The industrial site has frequency conversion control equipment, high-power electromagnetic starting equipment, GPS high-frequency signal wireless transceivers and other systems that have EMC interference sources. It is necessary to analyze and determine the interference signal processing solutions based on the characteristics of different interference sources and system control signals.

1, the sensor output analog signal interference
The installation of ISO series analog signal isolation amplifier at the output of the sensor can effectively solve the attenuation and EMC interference during the transmission of analog signals and enhance the stability and reliability of the display control system. Analog Signal Isolation Amplifier for EMC immunity of frequency converter: ISO EM UPOM series is equipped with input signal interference suppression filter circuit and output interference harmonic wave absorption circuit in IC to enhance EMC immunity and high-frequency signal spatial interference. . It is especially suitable for occasions where frequency conversion control equipment, high-power electromagnetic starting, GPS high-frequency signal wireless transceiver devices are on site.

2, spatial interference of high frequency signal radiation
Each control system and equipment shall be respectively equipped with metal shield boxes (different metal components used in different frequency bands) and the housing shall be reliably grounded. The signal transmission transmission lines shall be shielded with twisted pair cables.

3. Remote communication line interference of RS232/RS485 Install DC-DC isolation module power supply on RS232/RS485 communication interface, and isolate the communication power supply from other power supplies. Twisted-pair shielded cables (shield ground) are also used for signal communication transmission lines.

4. Interference in the system power supply circuit There are high-current thyristors, frequency conversion control equipment, and high-power electromagnetic starters on the site, which will have a distorting effect on the power supply system's power supply parameters. Through the power circuit, interference signals will enter the various control devices on site. Therefore, first of all, make sure that each device on the site is well grounded, and the power supply of each device should be equipped with its matched power supply filter (low-pass EMI filter or suppressing reactor).

Analog Signal Isolation Amplifier Bandwidth and Frequency Response of Isolated Transmitters Industrial Field Specifications Selection Application Reference:

1. When the analog signal is in slow frequency (<50Hz) (such as measuring temperature, pressure, displacement, flow, etc.), an isolation amplifier with small bandwidth and low frequency response can be selected: ISO EM U(A)-POM series products ( M: indicates low frequency noise). Therefore, in the inverter control system, in order to suppress and isolate the EMC interference, the ISO EM UPOM series of isolation amplifiers are often used.

2, analog signal in the high frequency of change (> 2KHz) occasions (such as measuring the speed, adjust the high-speed electronic switch, switching power supply PWM control, etc.), in order to ensure the integrity and reliability of the collected data, often used high bandwidth, high and low frequency Isolation Amplifier: ISO EM U(A)-POH Series Products

(H: indicates high frequency).

3. Most systems other than high frequency and low frequency response environments have chosen conventional frequency response (2K) products: ISO EM APO or ISO EM UPO series.

4. For the field environment with strong magnetic interference (high-frequency electromagnetic high-current load) occasions Opto-isolated amplifiers can be used: ISO U(A)-POM series.


Commonly Used Isolation Amplifier Isolation Transmitter Related Products Field Matching, Application Selection Technical Reference (pdf download):

1. Latest Application of Isolation Amplifiers: Field Frequency Bandwidth Matching with Isolated Transmitter Frequency Response Matching Technology

2, IC packaging isolation amplifier isolation transmitter signal and power supply part of the external protection circuit

3, ISO mV series: millivolt-level analog micro-signal special isolation amplifier IC

4. ISO EM U(A)-POT Series: Zero-Gain Adjustable Analog Isolation Amplifier Isolation Transmitter

5, ISO EM A (U)-POS series: input-end power distribution isolated transmitter IC

6. ISO EM U(A)-PO-SD Series: Input and Output Isolation Transmitter ICs with Adjustable Zero Gain

7. ISO EM-U(A)-POO Series: 1 input to 2 output low-cost, small-sized IC packaged analog isolation transmitter isolation amplifier

8. ISO EM APO Series: 0-±10V bidirectional DC (voltage/current) signal isolation amplifier isolation transmitter IC

9, DIN3 ISOEM UPO (APO) Series: Single DIN35 rail installation of low-cost, low-volume isolated transmitter

10, DIN 1X2 ISOEM U (A)-PO Series: One in and two out DIN35 rail mounting isolation transmitter

11. DIN 2X1 CPO series: 2 input and 1 output analog average isolation transmitter

12, DIN 2X2 ISOEM U (A)-PO series: two in two out of DIN35 rail mounting isolation transmitter

13, DIN 1X3 ISOEM U (A)-PO series: One in and three out DIN35 rail mounting isolation transmitter

14, DIN 1X4 series: One input and four analog signal isolation transmitter isolation amplifier

15, DIN ISO AC series: Passive two-wire AC to DC (AC/DC) signal isolation transmitter

16. ISO EMH 4-20mA Series: Special High-Isolation Safety Barriers for Track Voltage Monitoring

17. ISO FPO Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC

18, ISO U (A)-PF series: analog signal to frequency pulse signal (V / F) isolated transmitter IC

19, ISO EM RMS-PO series: analog true rms signal isolation transmitter isolation amplifier

Isolation Amplifier Isolated Transmitter IC Dimensions and PCB Layout Size Reference (SIP12 PiN):

Isolation Amplifier Isolation Transmitter IC, ISO EM Series Typical Application Wiring Diagram (ISO EM APO / ISO EM UPO):

Zero-point, gain adjustable isolation amplifier IC, ISO EM-T series typical application wiring diagram (ISO EM APOT / ISO EM UPOT):

Input isolation isolated distribution transmitter IC, ISO EM-S series typical application wiring diagram (ISO EM APOS / ISO EM UPOS):

ISO EM Series Analog Isolation Amplifier Isolated Transmitter, Product Outline and Installation Reference

Incremental Encoder

Incremental encoders provide speed, direction and relative position feedback by generating a stream of binary pulses proportional to the rotation of a motor or driven shaft. Lander offers both optical and magnetic incremental encoders in 4 mounting options: shafted with coupling, hollow-shaft, hub-shaft or bearingless. Single channel incremental encoders can measure speed which dual channel or quadrature encoders (AB) can interpret direction based on the phase relationship between the 2 channels. Indexed quadrature encoders (ABZ) are also available for homing location are startup.

Incremental Encoder,6Mm Solid Shaft Encoder,Hollow Rotary Encoder,Elevator Door Encoder

Jilin Lander Intelligent Technology Co., Ltd , https://www.jilinlandermotor.com